Rated Voltage:48V

Maximum Current:1.3 A

Gear Ratio:5:1

No - load Speed:12000 r/min

Stall Torque:73mNm

Continuous Power:16 W

Phase Resistance:3.2Ω

Phase Inductance:183μH

Outer Diameter:12.7mm

    Description

    ISO 13485 Certified

    ISO 13485 Certified OEM-Equivalent Repair Part for ENT & Orthopedic Surgery

    Our premium replacement motor for Medtronic M2 Straightshot microdebrider is a precision-engineered medical device purpose-built for the repair and maintenance of Medtronic M2 series shaver handpieces. Manufactured in strict accordance with ISO 13485:2016 medical device quality management standards, this motor delivers consistent surgical-grade power, reliable long-term performance, and exceptional durability, making it the cost-effective alternative to original Medtronic replacement parts for healthcare facilities and medical equipment service providers worldwide.

    Fully compatible with Medtronic M2 Straightshot handpiece models REF 18-97200, 18-96200, and 18-97100, this motor is designed to meet the exacting demands of minimally invasive surgeries across otolaryngology (ENT), orthopedics, and sports medicine specialties.

    OEM-Level Perfect Fit: Direct Drop-In Replacement

    Engineered using advanced 3D scanning and reverse engineering technology, our Medtronic M2 replacement motor features an exact 1:1 dimensional match to the original factory motor. This precision design ensures seamless integration with all internal components of your M2 Straightshot handpiece, eliminating the need for any modifications, drilling, or wiring adjustments during repair.

    Key benefits of our perfect-fit design:

    • Rapid repair turnaround: Reduces handpiece downtime from days to hours, minimizing disruption to surgical schedules.
    • Identical performance: Matches the original motor's speed range, torque output, and power characteristics.
    • Seamless compatibility: Works flawlessly with all original Medtronic M2 handpiece components.
    • Plug-and-play installation: Can be installed by any qualified biomedical engineer without specialized training.

    Autoclavable & Built for Clinical Durability

    Constructed from premium medical-grade stainless steel and high-temperature resistant engineering polymers, our Medtronic M2 Straightshot motor is designed to withstand the harsh conditions of repeated hospital sterilization cycles.

    • Full autoclave compatibility: Safe for standard 134°C/273°F high-pressure steam sterilization.
    • Superior corrosion resistance: Resists rust, pitting, and degradation caused by surgical debris.
    • Extended cycle rating: Rated for over 1000 sterilization cycles.
    • Reduced total cost of ownership: Lowers long-term maintenance expenses by up to 70%.

    100% Pre-Shipment Tested for Reliability

    Every motor undergoes a rigorous multi-stage quality control process to ensure zero defects:

    1. Dimensional accuracy verification: 100% inspection of all critical dimensions.
    2. Speed and torque calibration: Verified to match original Medtronic specifications.
    3. Thermal stability testing: Continuous 8-hour runtime tests to ensure no overheating.
    4. Sterilization cycle validation: Subjected to 50+ consecutive autoclave cycles.
    5. Full system compatibility testing: Tested with genuine Medtronic M2 power consoles.
    6. Electrical safety testing: Inspected for insulation resistance and leakage current.

    All motors come with a 12-month comprehensive warranty against manufacturing defects.

    Exact Compatibility List

    Shaver Handpieces:
    • REF 18-97200: M2 Straightshot Microdebrider
    • REF 18-96200: M2 Straightshot Shaver
    • REF 18-97100: M2 Straightshot High-Speed
    Systems & Accessories:
    • All M2 Straightshot & Evolution Consoles
    • All original M2 blades, burrs, and attachments

    Wide Range of Clinical Applications

    Otolaryngology (ENT) Surgery

    • Endoscopic sinus surgery (ESS) and FESS
    • Nasal polypectomy, turbinate reduction, and septoplasty
    • Tonsillectomy and adenoidectomy
    • Laryngeal polyp removal and middle ear surgery

    Orthopedic & Sports Medicine Surgery

    • Knee arthroscopy: Meniscectomy, chondroplasty, and ACL reconstruction
    • Shoulder arthroscopy: Rotator cuff and labral tear repair
    • Elbow, wrist, and ankle debridement
    • Hip arthroscopy and FAI treatment

    Why Choose Us?

    • ISO 13485 Certified facility
    • Unbeatable Value: Save up to 70%
    • Fast Global Shipping: Large inventory
    • Expert Technical Support: 24/7 assistance
    • Bulk Order Discounts for distributors
    • Custom OEM Services & private labeling

    Ready to restore your equipment's performance?

    📧 Email: christy@endotronicintl.com | 💬 WhatsApp: +86 15152885337

    Detail Image

    • detail1

      detail1

    • detail2

      detail2

    • detail3

      detail3

    Leave Your Message

    Your Name*

    Phone Number

    Company

    Remarks*

    reset